Flushometers - Optima Exposed Water Closet Flushometers
|
|
Optima Exposed Water Closet Flushometers |
|
Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer for either left or right hand supply with the following features:
- PERMEX™ Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass
- OPTIMA® EL-1500-L Self-Adaptive Infrared Sensor with Indicator Light
- User friendly three (3) second Flush Delay
- Courtesy Flush Override Button
- Two (2) Chrome Plated Wall Cover Plates (for 2-gang Electrical Box) with Vandal Resistant Screws
- 1” I.P.S. Screwdriver Bak-Chek® Angle Stop
- Free Spinning Vandal Resistant Stop Cap
- Sweat Solder Adapter with Cover Tube and Cast Wall Flange with Set Screw
- Adjustable Tailpiece
- High Back Pressure Vacuum Breaker Flush Connection with One-Piece Bottom Hex Coupling Nut, Spud Coupling and Flange for 1-1/2" Top Spud
- High Copper, Low Zinc Brass Castings for Dezincification Resistance
- Non-Hold-Open Integral Solenoid Operator, Fixed Metering Bypass and No External Volume Adjustment to Ensure Water Conservation
- 100% of the energy used in manufacturing is offset with Renewable Energy Sources – Wind Energy
Valve Body, Cover, Tailpiece and Control Stop shall be in conformance with ASTM Alloy Classification for Semi-Red Brass. Valve shall be in compliance to the applicable sections of ASSE 1037, ANSI/ASME A112.19.2, and Military Specification V-29193. Installation conforms to ADA requirements. |
|
Optima® Flushometers operate automatically and ensure access and ease of use by the disabled. By eliminating the need for manual operation, the spread of disease is greatly reduced and they are less susceptible to the abuses of user operation.
|
| Product Documentation |
|
 |
Specification Sheet |
|
|
Exposed, Sensor Operated Royal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|157.33 KBytes | 6/12/2008 |
|
|
Exposed, Sensor Activated Royal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:0|226.48 KBytes | 6/12/2008 |
|
|
Exposed, Sensor Operated Royal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|151.00 KBytes | 6/12/2008 |
|
|
Exposed, Sensor Operated Royal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|150.92 KBytes | 6/12/2008 |
|
|
Exposed, Sensor Operated Regal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|151.65 KBytes | 6/11/2008 |
|
|
Exposed, Sensor Operated Regal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|149.88 KBytes | 6/11/2008 |
|
|
Exposed, Sensor Operated Regal® Model Water Closet Flushometer, for floor mounted or wall hung top spud bowls. - Top Spud 1-1/2 inch |
English |
rev:1|150.43 KBytes | 6/11/2008 |
|
|
Exposed, Sensor Activated Regal® Model Service Sink Flushometer, for use with top spud Service Sinks. - Top Spud 1-1/2 inch |
English |
rev:0|307.52 KBytes | 9/17/2008 |
|
|
|
 |
Installation Instruction |
|
|
Installation Instructions for Optima Systems Sensor Activated Royal, Sloan & Regal Concealed and Exposed Water Closet Flushometer Installations. - |
English |
rev:3|639.74 KBytes | 7/9/2008 |
|
|
Electrical box rough-in template for sensor operated exposed water closet flushometers. - |
|
rev:0b|92.70 KBytes | 7/2/2008 |
|
|
Installation instructions for Optima® ES-S Flushometer electrical box positioning and support kit for exposed closet and urinal installations - Top Spud |
|
rev:0|217.85 KBytes | 7/9/2008 |
|
|
Installation instructions for Optima sensor replacement kits. - |
|
rev:1|37.96 KBytes | 7/2/2008 |
|
|
|
 |
Maintenance Guide |
|
|
Maintenance Guide for Optima Sensor Operated Water Closet and Urinal Flushometers. - Top Spud and Back Spud 3/4 inch 1-1/4 inch 1-1/2 inch |
English |
rev:0b|545.76 KBytes | 7/14/2008 |
|
|
|
|
|
|
|
|
|
|